Infrared inspection is only as valuable as the
methods used to collect, evaluate, and document
the data. ThermaVista uses structured inspection
practices informed by recognized IEC and ANSI/NETA
standards to support photovoltaic and electrical
commissioning and maintenance.
A Thermal Image Is Evidence.
A Proper Inspection Provides Context.
Thermal cameras detect infrared radiation and
provide information about surface temperature
patterns. But meaningful interpretation also
depends on system load, environmental conditions,
emissivity, reflected radiation, equipment
characteristics, and measurement technique.
Recognized inspection standards help make
thermographic observations more consistent,
repeatable, and useful for engineering and
maintenance decisions.
IEC TS 62446-3:2017
Outdoor Infrared Thermography
of PV Systems
Establishes requirements for inspecting
photovoltaic modules and plants using
infrared thermography during operation.
Reliable PV Inspection Starts With
Controlled Conditions
Solar thermal inspection depends on sufficient
irradiance and meaningful electrical operation.
Wind, clouds, reflections, and viewing geometry
can affect temperature measurements and the
visibility of thermal anomalies.
Irradiance:
Sufficient and stable sunlight to support
meaningful thermal contrast.
Wind:
Conditions evaluated to limit convective
cooling effects.
System operation:
Appropriate PV operating conditions during
inspection.
Viewing geometry:
Suitable camera positioning to manage
reflections and resolve targets.
Documentation:
Thermal images, measurements, site conditions,
and findings associated with identifiable assets.
These practices help separate genuine thermal
abnormalities from artifacts caused by unsuitable
inspection conditions.
INSPECTION METHODOLOGY
Measurement Quality Depends on
More Than Camera Resolution
ThermaVista considers operating conditions,
equipment characteristics, and environmental
influences when acquiring and interpreting
thermal data.
System Loading
Electrical heating is load-dependent.
Equipment must operate under conditions
suitable for the inspection objective.
Emissivity
Surface emissivity affects apparent temperature.
Measurement parameters must account for
material and surface characteristics.
Reflected Radiation
Reflective electrical surfaces can produce
misleading apparent temperatures that require
careful evaluation.
Temperature Comparison
Similar components under comparable operating
conditions can provide useful reference
temperatures and ΔT measurements.
Viewing Geometry
Distance, viewing angle, focus, and spatial
resolution affect measurement reliability
and anomaly detection.
Environmental Conditions
Ambient temperature, solar heating, wind,
and weather can change the observed thermal
response of equipment.
SYSTEM LIFECYCLE
The Right Inspection at the Right Time
Electrical commissioning, acceptance, and
maintenance serve different objectives.
Thermography can support each stage when
appropriately specified and performed.
1InstallConstruction and assembly
2CommissionANSI/NETA ECS
3AcceptANSI/NETA ATS
4OperateEstablish baseline condition
5MaintainANSI/NETA MTS
Thermographic findings support engineering,
commissioning, and maintenance decisions;
they do not replace required electrical tests.
STANDARDS COMPARISON
Which Standard Applies to Your Project?
Standard
Primary Purpose
Lifecycle Stage
ThermaVista Application
IEC TS 62446-3:2017
Outdoor infrared inspection
of operating PV modules and plants
Thermographic support for
commissioning verification
ANSI/NETA ATS-2025
Electrical acceptance testing
Prior to acceptance
Infrared inspection support
for applicable equipment
ANSI/NETA MTS-2023
Maintenance testing and
condition evaluation
In-service equipment
Periodic electrical thermography
and condition trending
DOCUMENTED RESULTS
Standards-Aligned Inspection Should
Produce Actionable Documentation
Reports should allow maintenance and
commissioning personnel to identify the
affected equipment, understand the observation,
and determine the appropriate next step.
Inspection Conditions
Operating load, environmental measurements,
relevant camera settings, and site information.
Thermal Evidence
Radiometric infrared imagery with
corresponding visible-light documentation.
Asset Identification
Site, building, equipment, component,
array, or module location.
Temperature Analysis
Observed temperatures, reference
temperatures, and relevant ΔT comparisons.
Finding Classification
Thermal observations and applicable
classification or prioritization criteria.
Recommended Follow-Up
Specific components requiring investigation,
corrective action, or future monitoring.
INSPECTION LIMITATIONS
Appropriate Access, Qualified Personnel,
and Defined Responsibilities
Thermographic inspection of energized
equipment requires coordination with the
facility's electrical safety program.
Access to energized equipment must be
evaluated under applicable electrical
safety requirements.
Removal of electrical covers or barriers
may require qualified electrical personnel.
Arc-flash and shock hazards must be
evaluated before exposure.
PPE, approach boundaries, permits, and
work practices must be addressed as applicable.
Thermography cannot reveal every electrical
defect, particularly where components are
obstructed or operating conditions are unsuitable.
PROFESSIONAL REPRESENTATION
Standards-Aligned Does Not Mean
Standards-Certified
ThermaVista references applicable technical
standards to inform thermographic inspection
practices. Specific inspection scope and
acceptance criteria are established by
project requirements and agreement.
Important distinction:
Use of IEC and ANSI/NETA standards as technical
references does not imply endorsement by IEC or
NETA, certification of ThermaVista by either
organization, or accreditation as a NETA
Accredited Company. Thermographic inspection
is not a substitute for a complete electrical
commissioning, acceptance, or maintenance
testing program.
FREQUENTLY ASKED QUESTIONS
Standards & Thermography FAQ
What is IEC TS 62446-3?
IEC TS 62446-3 is a technical specification
addressing outdoor infrared thermography
of operating photovoltaic modules and plants,
including inspection equipment, environmental
conditions, procedures, reporting, personnel
qualifications, and guidance for classifying
thermal abnormalities.
What is the difference between
ANSI/NETA ECS and ATS?
ECS addresses the broader electrical
commissioning process, while ATS focuses
on acceptance testing and evaluation of
electrical power equipment and systems.
Both may apply to a new installation
depending on project requirements.
Which standard applies to an existing
electrical system?
ANSI/NETA MTS addresses maintenance testing
of electrical equipment already in service.
IEC TS 62446-3 may also be applicable to
outdoor infrared inspection of operating
photovoltaic systems.
Does thermography replace other
electrical testing?
No. Thermal imaging is a complementary
condition assessment method. Other electrical
testing, visual inspections, functional
verification, and commissioning activities
may be required to establish equipment
performance and compliance.
Can thermography identify a loose connection?
Abnormal heating may be consistent with
a high-resistance connection, but thermography
alone generally cannot prove the specific
mechanical or electrical root cause.
Further evaluation may be required.
Are inspections performed while equipment
is operating?
Many thermographic inspections require
equipment to operate under meaningful load.
Conditions and safety procedures must be
appropriate for the equipment and inspection
objectives.
THERMAVISTA INSPECTIONS
Inspection Methods That Support
Better Decisions.
ThermaVista provides aerial PV and
ground-based electrical thermography
for commissioning and maintenance
throughout San Diego, Orange,
and Riverside Counties.